University Clinic Munich Grosshadern of ENT Department

Prof. Dr. Müller implants a SYNCHRONY CI in a 2 year old patient presenting slight variation of the facial nerve. Prof. Dr. Müller demonstrates structure preservation techniques with RW insertion of a STANDARD electrode array and the Electrode Fixation Clip.

University Medical Center Rostock: Otto Körner ENT Clinic

Prof. Dr. Mlynski utilizes a VIBRANT SOUNDBRIDGE 503 middle ear implant and a Vibroplasty short-process incus coupler for a 50 year old patient with sensorineural hearing loss and chronic otitis externa.

Collaboration between Madras ENT Research Foundation Ltd. and The Voluntary Health Services

Prof. Dr. Mohan Kameswaran and Dr. M. C. Vasudevan demonstrate the implantation with CONCERTO Auditory Brainstem Implant in a 4-year-old bilaterally congenitally deaf patient whose cochleae are present but no auditory nerves on either side.

Madras ENT Research Foundation (P) Ltd.

Prof. Dr. Mohan Kameswaran demonstrates the implantation of SONATA cochlear implant in a 5-year-old patient presenting with congenital bilateral deafness. The patient is suffering from type-II incomplete partition defect and a large vestibular aqueduct. The patient was implanted with a FORM19 electrode via cochleostomy approach.

University Hospital Innsbruck

Ass. Prof. PD Dr. med. Joachim Schmutzhard performs a VIBRANT SOUNDBRIDGE (VORP 503) implantation in a 65 year old female patient suffering from profound mixed hearing loss, due to radical cavity. For coupling of the FMT to the round window a RW-Soft-Coupler is used.

King Saud University, Riyadh

Prof. Dr. med. Abdulrahman Hagr performs simultaneous Cochlear Implantations using MED-EL SYNCHRONY Implants with FLEX28 Electrodes on a 22 month-old girl with unknown cause of hearing loss, using minimal invasive procedures.

University Hospital Innsbruck

Assoz. Prof. Priv.-Doz. Dr.med.univ. Joachim Schmutzhard performs a BONEBRIDGE (BCI 602) implantation in a 37 year old female patient suffering from conductive hearing loss, due to atresia.

University Hospital Halle (Saale), Martin Luther University Halle-Wittenberg

Prof. Dr. med. Stefan Plontke performs a VIBRANT SOUNDBRIDGE (VORP 503) implantation in a 55 year old male patient suffering from bilateral mild to moderate sensorineural hearing loss. For attachment of the FMT to the long process of the incus he uses an Incus-LP-Coupler.

La Paz University Hospital Madrid

Patient is a 52 year old man who already underwent several middle ear surgeries for cholesteatoma removal resulting in an open cavity and conductive hearing loss. Dr. Lassaletta performs a subtotal petrosectomy and afterwards Prof. Dr. Gavilán implants a BONEBRIDGE (BCI 601) using 1mm BCI Lifts in order to reduce drilling depth.

Sun Yat-Sen Memorial Hospital

Prof. Dr. Suijun Chen performs a BONEBRIDGE (BCI 601) implantation in an 5 year old male patient suffering from bilateral moderate conductive hearing loss due to atresia. To reduce drilling depth of the bone bed, 2mm BCI Lifts are used. Since pinna reconstruction is planned at a later stage, special considerations for size and location of incision are made.

St. Petersburg ENT and Speech Research Institute

Dr. Kuzovkov demonstrates the implantation of a CONCERTO PIN with STANDARD electrode array in a 3 year old bilaterally congenitally deaf patient with an attempt to provide the full coverage and best pitch-matching outcome with full electrode insertion.

Toronto Sunnybrook Health Sciences Centre

Dr. Joseph Chen demonstrates the cochlear implantation on an older adult patient who has a unilateral progressive deafness over a long period of time with his choice of SYNCHRONY implant and FLEX28 electrode for structure and hearing preservation.

Toronto Sunnybrook Health Sciences Centre

Dr. Joseph Chen demonstrates the cochlear implantation on a 35 year old man who has Cogan’s syndrome and received his first implant in 2010, and now he receives his second implant for bilateral implantation. SYNCHRONY PIN implant and FLEX28 electrode is used for this patient.

Royal Victoria Hospital Belfast

Dr. Toner implants a BONEBRIDGE (BCI 601) in a 9 year old boy suffering from single sided deafness. The device is implanted on the right (deaf) side and the BC-FMT (transducer) is placed in a position posterior to the external auditory canal and inferior to the temporal line.

Addenbrooke's Hospital, Cambridge

Dr. Donnelly performs a bilateral VIBRANT SOUNDBRIDGE (VORP 503) implantation in an 11 year old male patient suffering from bilateral moderate conductive hearing loss due to meatal stenosis. Patient previously had been rehabilitated with percutaneous bone conduction devices, but due to multiple revision surgeries patient and his parents asked for an intact skin solution. Dr. Donnelly uses a surgical technique which sees the FMT (transducer) being placed on the head of the stapes. For the attachment of the FMT to the head of the stapes he uses a CliP-Coupler.

Kuopio University Hospital

Dr. Aarno Dietz demonstrates a supra-meatal cochlear implant approach on local anaesthesia for an 84 year old female patient. For this case, FORM24 electrode array together with SYNCHRONY PIN implant are used for better control to complete electrode insertion through supra-meatus.

Universitätsklinikum Schleswig-Holstein

Dr. Frenzel implants a VIBRANT SOUNDBRIDGE (VORP 503) in a 8 year old female patient suffering from bilateral conductive hearing loss due to microtia. In this video he is implanting the left side, but the patient will also receive a VSB on the other side. Dr. Frenzel uses a surgical technique which sees the FMT (transducer) being placed on the head of the stapes. For the attachment of the FMT to the head of the stapes he uses a CliP-Coupler.

Fiona Stanley Hospital, Perth

Prof. Dr. Gunesh Rajan demonstrates the cochlear implantation on a 42 year old female patient who previously has been diagnosed with meningitis. The early intervention allows possible management of fibrosis intra-cochlea and completion of electrode insertion using FLEX28 electrode array and SYNCHRONY implant.

University Medical Center Mainz

Dr. Mewes implants a VIBRANT SOUNDBRIDGE (VORP 503) in a 67 year old female patient suffering from SNHL. She is unable to wear conventional hearing aids due to medical problems in her external auditory canal. Dr. Mewes uses a surgical technique which does not require a facial recess. For the attachment of the FMT (transducer) to the short process of the incus he uses an SP-Coupler.

University Clinic Munich Grosshadern of ENT Department

Dr. Hempel implants a VIBRANT SOUNDBRIDGE (VORP 502) in an atresia child with a pure CHL. Middle ear is malformed and middle ear cavity is small. Since stapes is still present and footplate is mobile, Dr. Hempel uses a CliP-Coupler (on head of the stapes) in order to attach the FMT.

London Health Sciences Centre

Prof. Parnes demonstrates a series of cochlear implantations on the right ear of an elder female patient who has bilaterally progressive hearing loss with CONCERTO FLEX28 electrode.

London Health Sciences Centre

Prof. Parnes demonstrates a series of cochlear implantations on the left ear of an elder female patient who has bilaterally progressive hearing loss with CONCERTO FLEX28 electrode.

Universitätsklinikum St. Pölten

Prof. Sprinzl demonstrates the implantation of a SOUNDBRIDGE, the active middle ear implant VORP 502, in a 48 year old patient with a mixed hearing loss, who had previously undergone several middle ear surgeries due to cholesteatoma. Prof. Sprinzl uses a RW Vibroplasty where the FMT is placed, in combination with a RW-Coupler, onto the RW membrane.

UZA Antwerp Belgium

Prof. Dr. Van de Heyning utilizes a CONCERTO PIN with FLEX28 electrode array to demonstrate structure preservation techniques and tight periosteum pocket for a 58 year old patient.

University Clinic Munich Grosshadern of ENT Department

Prof. Müller implants a BONEBRIDGE active bone conduction implant in a 22 year old female patient suffering from MHL due to recurrent OM with effusion. Prof. Müller performs a placement in sinodural angle using 1mm BCI Lifts.

Bundeswehrkrankenhaus Ulm

Prof. Dr. Tisch demonstrates the implantation of a SOUNDBRIDGE, the active middle ear implant VORP 502 in a 53 year old patient with a sensorineural hearing loss who was using hearing aids without success. Prof Tisch uses a Incus Vibroplasty where he couples the FMT onto the long process of the incus.

St. Petersburg ENT and Speech Research Institute

Dr. Kuzovkov demonstrates the implantation of a CONCERTO PIN with STANDARD electrode array in a 2 year old congenitally deaf patient with an attempt to provide the best pitch-matching outcome with full electrode insertion.

Universitätsklinikum St. Pölten

Prof. Dr. Sprinzl demonstrates the implantation of a SOUNDBRIDGE, the active middle ear implant VORP 502 in a 21 year old patient with a mixed hearing loss who had previously undergone several middle ear surgeries due to cholesteatoma. Prof. Sprinzl uses a RW Vibroplasty in a dry radical cavity where the FMT is placed directly onto the RW membrane.

Klinikum Stuttgart: Olgahospital

Prof. Dr. Koitschev demonstrates the implantation of a BONEBRIDGE active bone conduction implant in an 11 year old patient with atresia/microtia and conductive hearing loss.

Matsumoto Shinshu Hospital

Prof. Usami demonstrates hearing preservation techniques in a 40 year old patient with near-normal residual hearing in the low frequencies. Prof. Usami utilizes the CONCERTO PIN with FLEX24 electrode array. FLEX24 is intended to support residual hearing to enable combined electric-acoustic stimulation (EAS). The endoscope is also used during the surgery.

The General Hospital of the People's Liberation Army, Beijing, China

Prof. Dr. Dai utilizes a CONCERTO and FLEX28 electrode array for structure preservation techniques for a 12 month old patient with residual low frequency hearing.

University of North Carolina, School of Medicine

Dr. Pillsbury demonstrates the placement of MED-EL CONCERT in a tight periosteum pocket with positioning for use with the RONDO Single-Unit Processor. The 64 year old patient experienced no complications despite several comorbidities.

St. Petersburg ENT and Speech Research Institute

Dr. Kuzovkov demonstrates the implantation of a CONCERTO PIN with STANDARD electrode array in a 9 year old patient with ossification in the basal turn of the cochlea.